Short-Circuit Study of Medium Voltage GaN Cascodes, P-GaN HEMTs and MISHEMTs

This paper studies by experimentation and physics-based simulation the Short-Circuit (SC) capability of several normally-off 600-650 V Gallium Nitride High-Electron-Mobility Transistors (GaN HEMTs): cascodes, p-GaN, and GaN Metal-Insulator-Semiconductor HEMTs (MISHEMTs).

https://www.imb-cnm.csic.es/es/node/373

Robust L-malate bienzymatic biosensor to enable the on-site monitoring of malolactic fermentation of red wines

The development of an amperometric biosensor for L-malate determination showing long-term stability is reported in this work.

https://www.imb-cnm.csic.es/es/node/374

Solid contact ion sensor with conducting polymer layer copolymerized with the ion-selective membrane for determination of calcium in blood serum

A new solid contact ion selective electrode with intermediate conducting polymer (CP) layer formed by electropolymerization on a gold electrode of a bifunctional monomer, n-phenyl-ethylenediaminemethacrylamide (NPEDMA), which contains a methacrylamide group attached to aniline, is presented.

https://www.imb-cnm.csic.es/es/node/375

Impedimetric antimicrobial peptide-based sensor for the early detection of periodontopathogenic bacteria

The aim of the present study was to combine the use of miniaturized and integrated impedimetric transducers and antimicrobial peptide AMPs to obtain biosensors with high sensitivity to monitor bacterial colonization to prevent implant-related infections..

https://www.imb-cnm.csic.es/es/node/376

Multiple actuation microvalves in wax microfluidics

A new type of electrically controlled and fully integrated wax microvalve is described in this work. The valve is designed for multiple actuation and has a small footprint (< 0.5 mm2), fast response (< 0.3 s) and low energy consumption (< 35 mJ).

https://www.imb-cnm.csic.es/es/node/377

Polysilicon-chromium-gold intracellular chips for multi-functional biomedical applications

In this work, the feasibility of using multi-material pSi-Cr-Au intracellular chips for multifunctional applications by characterizing their interactions with two different cell lines, one tumorigenic and one non-tumorigenic has been explored.

https://www.imb-cnm.csic.es/es/node/378

Study From Cryogenic to High Temperatures of the High- and Low-Resistance-State Currents of ReRAM Ni–HfO2–Si Capacitors

 Resistive switching conduction in Ni/HfO2/Si capacitors is studied at temperatures ranging from 77 to 473 K. A model for the low-resistance state (LRS) consistent with the experimental data is proposed.

https://www.imb-cnm.csic.es/es/node/379

Festivals i trobades de divulgació

L'IMB-CNM participa regularment en esdeveniments anuals de divulgació científica.

https://www.imb-cnm.csic.es/es/noticias-divulgacion/divulgacion/festivales-y-encuentros-de-divulgacion

Festivals and outreach meetings

The IMB-CNM participates regularly in science awareness events.

https://www.imb-cnm.csic.es/es/noticias-divulgacion/divulgacion/festivales-y-encuentros-de-divulgacion

Festivales y encuentros de divulgación

El IMB-CNM participa regularmente en eventos de divulgacion para promover el conocimiento científico entre toda la sociedad.

https://www.imb-cnm.csic.es/es/noticias-divulgacion/divulgacion/festivales-y-encuentros-de-divulgacion