This website uses its own and third-party cookies for its operation, to maintain the session and to personalize the user's experience. For more information about the cookies used consult our cookies policy

Institute of Microelectronics of Barcelona IMB-CNM   

IMB-CNM Facebookchannel IMB-CNM Linkedin channel IMB-CNM Youtube channel IMB-CNM Instagram channel IMB-CNM Pinterest channel Login to IMB-CNM Intranet

Papers Web of Science 2015

1.Abramova, N.; Bratov, A., Title Monitoring Protamine-Heparin Interactions Using Microcapillary Impedimetric Sensor. Electroanalysis 2015, 27 (3), 663-669. DOI: 10.1002/elan.201400581.

2.Alayo, N.; Conde-Rubio, A.; Bausells, J.; Borrise, X.; Labarta, A.; Batlle, X.; Perez-Murano, F., Nanoparticles with tunable shape and composition fabricated by nanoimprint lithography. Nanotechnology 2015, 26 (44). DOI: 10.1088/0957-4484/26/44/445302.

3.Alexandru, M.; Banu, V.; Jorda, X.; Montserrat, J.; Vellvehi, M.; Tournier, D.; Millan, J.; Godignon, P., SiC Integrated Circuit Control Electronics for High-Temperature Operation. Ieee Transactions on Industrial Electronics 2015, 62 (5), 3182-3191. DOI: 10.1109/tie.2014.2379212.

4.Alonso, A.; Vigues, N.; Rodriguez-Rodriguez, R.; Borrise, X.; Munoz, M.; Muraviev, D. N.; Mas, J.; Munoz-Berbel, X., Activity-tunable nanocomposites based on dissolution and in situ recrystallization of nanoparticles on ion exchange resins. RSC Advances 2015, 5 (109), 89971-89975. DOI: 10.1039/c5ra16081b.

5.Annanouch, F. E.; Gracia, I.; Figueras, E.; Llobet, E.; Cane, C.; Vallejos, S., Localized aerosol-assisted CVD of nanomaterials for the fabrication of monolithic gas sensor microarrays. Sensors and Actuators B-Chemical 2015, 216, 374-383. DOI: 10.1016/j.snb.2015.03.076.

6.Annanouch, F. E.; Haddi, Z.; Vallejos, S.; Umek, P.; Guttmann, P.; Bittencourt, C.; Llobet, E., Aerosol-Assisted CVD-Grown WO3 Nanoneedles Decorated with Copper Oxide Nanoparticles for the Selective and Humidity-Resilient Detection of H2S. Acs Applied Materials & Interfaces 2015, 7 (12), 6842-6851. DOI: 10.1021/acsami.5b00411.

7.Ayan-Varela, M.; Paredes, J. I.; Guardia, L.; Villar-Rodil, S.; Munuera, J. M.; Diaz-Gonzalez, M.; Fernandez-Sanchez, C.; Martinez-Alonso, A.; Tascon, J. M. D., Achieving Extremely Concentrated Aqueous Dispersions of Graphene Flakes and Catalytically Efficient Graphene-Metal Nanoparticle Hybrids with Flavin Mononucleotide as a HighPerformance Stabilizer. Acs Applied Materials & Interfaces 2015, 7 (19), 10293-10307. DOI: 10.1021/acsami.5b00910.

8.Baez-Gaxiola, M. R.; Fernandez-Sanchez, C.; Mendoza, E., Gold cluster based electrocatalytic sensors for the detection of formaldehyde. Analytical Methods 2015, 7 (2), 538-542. DOI: 10.1039/c4ay02023e.

9.Bausells, J., Piezoresistive cantilevers for nanomechanical sensing. Microelectronic Engineering 2015, 145, 9-20. DOI: 10.1016/j.mee.2015.02.010.

10.Blanco-Roldan, C.; Quiros, C.; Sorrentino, A.; Hierro-Rodriguez, A.; Alvarez-Prado, L. M.; Valcarcel, R.; Duch, M.; Torras, N.; Esteve, J.; Martin, J. I.; Velez, M.; Alameda, J. M.; Pereiro, E.; Ferrer, S., Nanoscale imaging of buried topological defects with quantitative X-ray magnetic microscopy. Nature Communications 2015, 6. DOI: 10.1038/ncomms9196.

11.Brosel-Oliu, S.; Abramova, N.; Bratov, A.; Vigues, N.; Mas, J.; Munoz, F. X., Sensitivity and Response Time of Polyethyleneimine Modified Impedimetric Transducer for Bacteria Detection. Electroanalysis 2015, 27 (3), 656-662. DOI: 10.1002/elan.201400575.

12.Calaza, C.; Salleras, M.; Davila, D.; Tarancon, A.; Morata, A.; Santos, J. D.; Gadea, G.; Fonseca, L., Bottom-Up Silicon Nanowire Arrays for Thermoelectric Harvesting. Materials Today-Proceedings 2015, 2 (2), 675-679. DOI: 10.1016/j.matpr.2015.05.085.

13.Cartiglia, N.; Arcidiacono, R.; Baselga, M.; Bellan, R.; Boscardin, M.; Cenna, F.; Betta, G. F. D.; Fernndez-Martnez, P.; Ferrero, M.; Flores, D.; Galloway, Z.; Greco, V.; Hidalgo, S.; Marchetto, F.; Monaco, V.; Obertino, M.; Pancheri, L.; Paternoster, G.; Picerno, A.; Pellegrini, G.; Quirion, D.; Ravera, F.; Sacchi, R.; Sadrozinski, H. F. W.; Seiden, A.; Solano, A.; Spencer, N., Design optimization of ultra-fast silicon detectors. Nuclear Instruments & Methods in Physics Research Section a-Accelerators Spectrometers Detectors and Associated Equipment 2015, 796, 141-148. DOI: 10.1016/j.nima.2015.04.025.

14.Cases-Utrera, J.; Escude-Pujol, R.; Ibanez-Otazua, N.; del Campo, F. J., Development of an Automated Heavy Metal Analyser. Electroanalysis 2015, 27 (4), 929-937. DOI: 10.1002/elan.201400614.

15.Cavallaro, E.; Lange, J.; Paz, I. L.; Grinstein, S.; Baselga, M.; Greco, V.; Quirion, D.; Pellegrini, G., First measurements of segmented silicon tracking detectors with built-in multiplication layer. Nuclear Instruments & Methods in Physics Research Section a-Accelerators Spectrometers Detectors and Associated Equipment 2015, 796, 136-140. DOI: 10.1016/j.nima.2015.05.023.

16.Claramunt, S.; Wu, Q.; Maestro, M.; Porti, M.; Gonzalez, M. B.; Martin-Martinez, J.; Campabadal, F.; Nafria, M., Non-homogeneous conduction of conductive filaments in Ni/HfO2/Si resistive switching structures observed with CAFM. Microelectronic Engineering 2015, 147, 335-338. DOI: 10.1016/j.mee.2015.04.112.

17.Conejero-Muriel, M.; Rodriguez-Ruiz, I.; Martinez-Rodriguez, S.; Llobera, A.; Gavira, J. A., McCLEC, a robust and stable enzymatic based microreactor platform. Lab on a Chip 2015, 15 (20), 4083-4089. DOI: 10.1039/c5lc00776c.

18.Cruz, C.; Jover-Manas, G.; Matilla, O.; Avila, J.; Juanhuix, J.; Pellegrini, G.; Quirion, D.; Rodriguez, J., 10 mu m thin transmissive photodiode produced by ALBA Synchrotron and IMB-CNM-CSIC. Journal of Instrumentation 2015, 10. DOI: 10.1088/1748-0221/10/03/c03005.

19.Cumeras, R.; Figueras, E.; Davis, C. E.; Baumbach, J. I.; Gracia, I., Review on Ion Mobility Spectrometry. Part 1: current instrumentation. Analyst 2015, 140 (5), 1376-1390. DOI: 10.1039/c4an01100g.

20.Cumeras, R.; Figueras, E.; Davis, C. E.; Baumbach, J. I.; Gracia, I., Review on Ion Mobility Spectrometry. Part 2: hyphenated methods and effects of experimental parameters. Analyst 2015, 140 (5), 1391-1410. DOI: 10.1039/c4an01101e.

21.de Boer, W.; Dierlamm, A.; Hartmann, F.; Hoffmann, K. H.; Kornmayer, A.; Muller, T.; Nurnberg, A.; Pellegrini, G.; Printz, M.; Quirion, D., A fourfold segmented silicon strip sensor with read-out at the edges. Nuclear Instruments & Methods in Physics Research Section a-Accelerators Spectrometers Detectors and Associated Equipment 2015, 788, 154-160. DOI: 10.1016/j.nima.2015.03.082.

22.Diaz-Gonzalez, M.; Salvador, J. P.; Bonilla, D.; Marco, M. P.; Fernandez-Sanchez, C.; Baldi, A., A microfluidic device for the automated electrical readout of low-density glass-slide microarrays. Biosensors & Bioelectronics 2015, 74, 698-704. DOI: 10.1016/j.bios.2015.07.005.

23.Donmez, I.; Salleras, M.; Calaza, C.; Santos, J. D.; Gadea, G.; Morata, A.; Davila, D.; Tarancon, A.; Fonseca, L., Interdigitated design of a thermoelectric microgenerator based on silicon nanowire arrays. In Smart Sensors, Actuators, and Mems Vii; and Cyber Physical Systems, SanchezRojas, J. L.; Brama, R., Eds. 2015; Vol. 9517. DOI: 95172c10.1117/12.2178782.

24.Duenas, S.; Castan, H.; Garcia, H.; Fuentes, L. M.; Bailon, L.; Campabadal, F.; Rafi, J. M.; Gonzalez, M. B.; Takakura, K.; Tsunoda, I.; Yoneoka, M., Hole trap distribution on 2MeV electron irradiated high-k dielectrics. Journal of Vacuum Science & Technology B 2015, 33 (3). DOI: 10.1116/1.4915617.

25.Duran, S.; Duch, M.; Patino, T.; Torres, A.; Penon, O.; Gomez-Martinez, R.; Barrios, L.; Esteve, J.; Nogues, C.; Perez-Garcia, L.; Plaza, J. A., Technological development of intracellular polysilicon-chromium-gold chips for orthogonal chemical functionalization. Sensors and Actuators B-Chemical 2015, 209, 212-224. DOI: 10.1016/j.snb.2014.11.077.

26.Duran, S.; Novo, S.; Duch, M.; Gomez-Martinez, R.; Fernandez-Regulez, M.; Paulo, A. S.; Nogues, C.; Esteve, J.; Ibanez, E.; Plaza, J. A., Silicon-nanowire based attachment of silicon chips for mouse embryo labelling. Lab on a Chip 2015, 15 (6), 1508-1514. DOI: 10.1039/c4lc01299b.

27.Estrada-Leypon, O.; Moya, A.; Guimera, A.; Gabriel, G.; Agut, M.; Sanchez, B.; Borros, S., Simultaneous monitoring of Staphylococcus aureus growth in a multi-parametric microfluidic platform using microscopy and impedance spectroscopy. Bioelectrochemistry 2015, 105, 56-64. DOI: 10.1016/j.bioelechem.2015.05.006.

28.Evangelio, L.; Fernandez-Regulez, M.; Borrise, X.; Lorenzoni, M.; Fraxedas, J.; Perez-Murano, F., Creation of guiding patterns for directed self-assembly of block copolymers by resistless direct e-beam exposure. In Alternative Lithographic Technologies Vii, Resnick, D. J.; Bencher, C., Eds. 2015; Vol. 9423. DOI: 94232610.1117/12.2085830.

29.Farina, D.; Alvarez, M.; Marquez, S.; Dominguez, C.; Lechuga, L. M., Sensitivity analysis for improving nanomechanical photonic transducers biosensors. Journal of Physics D-Applied Physics 2015, 48 (33). DOI: 10.1088/0022-3727/48/33/335401.

30.Fernandez-Sanchez, C.; Rodriguez, J. A.; Dominguez, C., Synthesis of sol-gel SiO2-based materials using alkoxydisilane precursors: mechanisms and luminescence studies. Journal of Sol-Gel Science and Technology 2015, 73 (2), 417-427. DOI: 10.1007/s10971-014-3551-x.

31.Fleta, C.; Esteban, S.; Baselga, M.; Quirion, D.; Pellegrini, G.; Guardiola, C.; Cortes-Giraldo, M. A.; Lopez, J. G.; Jimenez'Ramos, M. C.; Gomez, F.; Lozano, M., 3D cylindrical silicon microdosimeters: fabrication, simulation and charge collection study. Journal of Instrumentation 2015, 10. DOI: 10.1088/1748-0221/10/10/p10001.

32.Fonseca, L.; Donmez, I.; Salleras, M.; Calaza, C.; Gadea, G.; Santos, J. D.; Morata, A.; Tarancon, A.; Iop, Improved thermal isolation of silicon suspended platforms for an all-silicon thermoelectric microgenerator based on large scale integration of Si nanowires as thermoelectric material. In 15th International Conference on Micro and Nanotechnology for Power Generation and Energy Conversion Applications, 2015; Vol. 660. DOI: 01211310.1088/1742-6596/660/1/012113.

33.Fraxedas, J.; Perez-Murano, F.; Gramazio, F.; Lorenzoni, M.; Trinidad, E. R.; Staufer, U., Continuous monitoring of tip radius during atomic force microscopy imaging. In Scanning Microscopies 2015, Postek, M. T.; Newbury, D. E.; Platek, S. F.; Maugel, T. K., Eds. 2015; Vol. 9636. DOI: 96360o10.1117/12.2196951.

34.Gadea, G.; Morata, A.; Santos, J. D.; Davila, D.; Calaza, C.; Salleras, M.; Fonseca, L.; Tarancon, A., Towards a full integration of vertically aligned silicon nanowires in MEMS using silane as a precursor. Nanotechnology 2015, 26 (19). DOI: 10.1088/0957-4484/26/19/195302.

35.Gago, A. S.; Esquivel, J. P.; Sabate, N.; Santander, J.; Alonso-Vante, N., Comprehensive characterization and understanding of micro-fuel cells operating at high methanol concentrations. Beilstein Journal of Nanotechnology 2015, 6, 2000-2006. DOI: 10.3762/bjnano.6.203.

36.Garcia-Cruz, A.; Lee, M.; Zine, N.; Sigaud, M.; Bausells, J.; Errachid, A., Poly(pyrrole) microwires fabrication process on flexible thermoplastics polymers: Application as a biosensing material. Sensors and Actuators B-Chemical 2015, 221, 940-950. DOI: 10.1016/j.snb.2015.06.084.

37.Giannetta, H. M. R.; Calaza, C.; Lamas, D. G.; Fonseca, L.; Fraigi, L., Electrical transport properties of V2O5 thin films obtained by thermal annealing of layers grown by RF magnetron sputtering at room temperature. Thin Solid Films 2015, 589, 730-734. DOI: 10.1016/j.tsf.2015.06.048.

38.Gimenez-Gomez, P.; Escude-Pujol, R.; Jimenez-Jorquera, C.; Gutierrez-Capitan, M., Multisensor Portable Meter for Environmental Applications. Ieee Sensors Journal 2015, 15 (11), 6517-6523. DOI: 10.1109/jsen.2015.2460011.

39.Gomes, H. L.; Medeiros, M. C. R.; Villani, F.; Canudo, J.; Loffredo, F.; Miscioscia, R.; Martinez-Domingo, C.; Ramon, E.; Sowade, E.; Mitra, K. Y.; Baumann, R. R.; McCulloch, I.; Carrabina, J., All-inkjet printed organic transistors: Dielectric surface passivation techniques for improved operational stability and lifetime. Microelectronics Reliability 2015, 55 (8), 1192-1195. DOI: 10.1016/j.microrel.2015.05.006.

40.Gonzalez, M. B.; Martin-Martinez, J.; Rodriguez, R.; Acero, M. C.; Nafria, M.; Campabadal, F.; Ayrnerich, X., Dedicated random telegraph noise characterization of Ni/HfO2-based RRAM devices. Microelectronic Engineering 2015, 147, 59-62. DOI: 10.1016/j.mee.2015.04.046.

41.Guardiola, C.; Fleta, C.; Rodriguez, J.; Lozano, M.; Gomez, F., Preliminary microdosimetric measurements with ultra-thin 3D silicon detectors of a 62 MeV proton beam. Journal of Instrumentation 2015, 10. DOI: 10.1088/1748-0221/10/01/p01008.

42.Guardiola, C.; Quirion, D.; Pellegrini, G.; Fleta, C.; Esteban, S.; Cortes-Giraldo, M. A.; Gomez, F.; Solberg, T.; Carabe, A.; Lozano, M., Silicon-based three-dimensional microstructures for radiation dosimetry in hadrontherapy. Applied Physics Letters 2015, 107 (2). DOI: 10.1063/1.4926962.

43.Guimera, A.; Gabriel, G.; Prats-Alfonso, E.; Abramova, N.; Bratov, A.; Villa, R., Effect of surface conductivity on the sensitivity of interdigitated impedimetric sensors and their design considerations. Sensors and Actuators B-Chemical 2015, 207, 1010-1018. DOI: 10.1016/j.snb.2014.10.134.

44.Guimera, X.; Moya, A.; Dorado, A. D.; Villa, R.; Gabriel, D.; Gabriel, G.; Gamisans, X., Biofilm dynamics characterization using a novel DO-MEA sensor: mass transport and biokinetics. Applied Microbiology and Biotechnology 2015, 99 (1), 55-66. DOI: 10.1007/s00253-014-5821-5.

45.Gutierrez-Capitan, M.; Baldi, A.; Gomez, R.; Garcia, V.; Jimenez-Jorquera, C.; Fernandez-Sanchez, C., Electrochemical Nanocomposite-Derived Sensor for the Analysis of Chemical Oxygen Demand in Urban Wastewaters. Analytical Chemistry 2015, 87 (4), 2152-2160. DOI: 10.1021/ac503329a.

46.Herrera-May, A. L.; Lara-Castro, M.; Lopez-Huerta, F.; Gkotsis, P.; Raskin, J. P.; Figueras, E., A MEMS-based magnetic field sensor with simple resonant structure and linear electrical response. Microelectronic Engineering 2015, 142, 12-21. DOI: 10.1016/j.mee.2015.06.009.

47.Illa, X.; Rebollo, B.; Gabriel, G.; Sanchez-Vives, M. V.; Villa, R., A SU-8 based flexible microprobe for close and distal recordings from the cortical network. In Bio-Mems and Medical Microdevices Ii, VanDenDriesche, S., Ed. 2015; Vol. 9518. DOI: 95180310.1117/12.2180454.

48.Jorda, X.; Esarte, J.; Perpina, X.; Vellvehi, M.; Argandona, G.; Aresti, M., Characterization of phase change material systems using a thermal test device. Microelectronics Journal 2015, 46 (12), 1195-1201. DOI: 10.1016/j.mejo.2015.09.022.

49.King, D.; Hedegaard, E. R.; Ackermann, T. N.; Rius, C.; Munoz-Berbel, X.; Knudsen, H.; Rodriguz-Rodriguez, I.; Dorado, B.; Alvarez, E.; Ducree, J.; Andres, V.; Simonsen, U.; Llobera, A., Living Photonics: Monitoring light propagation through cells (LiPhos). In Bio-Mems and Medical Microdevices Ii, VanDenDriesche, S., Ed. 2015; Vol. 9518. DOI: 95180m10.1117/12.2181306.

50.King, D.; Leiva, C. R.; Glynn, M.; de la Corta, B. J. D.; Cindric, S.; Kernan, D.; Garcia, V.; Llobera, A.; Hedegaard, E. R.; Simonsen, U.; Ducree, J., Living Photonics (LiPhos) Single Cell Analysis - Label Free Detection Methods. Acta Physiologica 2015, 215, 32-33.

51.Kitsara, M.; Cirera, J. M.; Aller-Pellitero, M.; Sabate, N.; Punter, J.; Colomer-Farrarons, J.; Miribel-Catala, P.; del Campo, F. J., Small-volume multiparametric electrochemical detection at low cost polymeric devices featuring nanoelectrodes. In Bio-Mems and Medical Microdevices Ii, VanDenDriesche, S., Ed. 2015; Vol. 9518. DOI: 95180z10.1117/12.2178908.

52.Kitsara, M.; Joanne, P.; Boitard, S. E.; Ben Dhiab, I.; Poinard, B.; Menasche, P.; Gagnieu, C.; Forest, P.; Agbulut, O.; Chen, Y., Fabrication of cardiac patch by using electrospun collagen fibers. Microelectronic Engineering 2015, 144, 46-50. DOI: 10.1016/j.mee.2015.02.034.

53.Kovylina, M.; Alayo, N.; Conde-Rubio, A.; Borrise, X.; Hibbard, G.; Labarta, A.; Batlle, X.; Perez-Murano, F., Au cylindrical nanocup: A geometrically, tunable optical nanoresonator. Applied Physics Letters 2015, 107 (3). DOI: 10.1063/1.4927053.

54.Kramberger, G.; Baselga, M.; Cindro, V.; Fernandez-Martinez, P.; Flores, D.; Galloway, Z.; Gorisek, A.; Greco, V.; Hidalgo, S.; Fadeyev, V.; Mandic, I.; Mikuz, M.; Quirion, D.; Pellegrini, G.; Sadrozinski, H. F. W.; Studen, A.; Zavrtanik, M., Radiation effects in Low Gain Avalanche Detectors after hadron irradiations. Journal of Instrumentation 2015, 10. DOI: 10.1088/1748-0221/10/07/p07006.

55.Kuo, C. N.; Lin, P. C.; Del Campo, F. J.; Tsai, Y. C., Construction of a Hydrogen Peroxide Biosensor on Interdigitated Microband Electrodes Fabricated by a Mix-and-Match Process. Journal of the Electrochemical Society 2015, 162 (7), B133-B137. DOI: 10.1149/2.0261507jes.

56.Laurenti, M.; Stassi, S.; Lorenzoni, M.; Fontana, M.; Canavese, G.; Cauda, V.; Pirri, C. F., Evaluation of the piezoelectric properties and voltage generation of flexible zinc oxide thin films. Nanotechnology 2015, 26 (21). DOI: 10.1088/0957-4484/26/21/215704.

57.Lee, M.; Lopez-Martinez, M. J.; Baraket, A.; Zine, N.; Esteve, J.; Plaza, J. A.; Ahmed, N.; Elaissari, A.; Jaffrezic-Renault, N.; Errachid, A., Combination of PDMS microfilters and micromixers based on flexible thermoplastic films for size sorting and mixing of microparticles. Journal of Applied Polymer Science 2015, 132 (25). DOI: 10.1002/app.42088.

58.Leon, J.; Perpina, X.; Sacristan, J.; Vellvehi, M.; Baldi, A.; Jorda, X., Functional and Consumption Analysis of Integrated Circuits Supplied by Inductive Power Transfer by Powering Modulation and Lock-In Infrared Imaging. Ieee Transactions on Industrial Electronics 2015, 62 (12), 7774-7785. DOI: 10.1109/tie.2015.2455024.

59.Leon, J.; Perpina, X.; Vellvehi, M.; Jorda, X.; Godignon, P., Local non invasive study of SiC diodes with abnormal electrical behavior. Solid-State Electronics 2015, 113, 35-41. DOI: 10.1016/j.sse.2015.05.008.

60.Lete, C.; Lupu, S.; Lakard, B.; Hihn, J. Y.; del Campo, F. J., Multi-analyte determination of dopamine and catechol at single-walled carbon nanotubes - Conducting polymer - Tyrosinase based electrochemical biosensors. Journal of Electroanalytical Chemistry 2015, 744, 53-61. DOI: 10.1016/j.jelechem.2015.03.005.

61.Llobera, A.; Juvert, J.; Gonzalez-Fernandez, A.; Ibarlucea, B.; Carregal-Romero, E.; Buttgenbach, S.; Fernandez-Sanchez, C., Biofunctionalized all-polymer photonic lab on a chip with integrated solid-state light emitter. Light-Science & Applications 2015, 4. DOI: 10.1038/lsa.2015.44.

62.Llobet, J.; Gerboles, M.; Sansa, M.; Bausells, J.; Borrise, X.; Perez-Murano, F., Fabrication of functional electromechanical nanowire resonators by focused ion beam implantation. Journal of Micro-Nanolithography Mems and Moems 2015, 14 (3). DOI: 10.1117/1.jmm.14.3.031207.

63.Llobet, J.; Gerboles, M.; Sansa, M.; Borrise, X.; Perez-Murano, F., Fabrication of functional electromechanical nanowire resonators by focused ion beam (FIB) implantation. In Alternative Lithographic Technologies Vii, Resnick, D. J.; Bencher, C., Eds. 2015; Vol. 9423. DOI: 94230k 10.1117/12.2085818.

64.Llobet, J.; Krali, E.; Wang, C.; Arbiol, J.; Jones, M. E.; Perez-Murano, F.; Durrani, Z. A. K., Resonant tunnelling features in a suspended silicon nanowire single-hole transistor. Applied Physics Letters 2015, 107 (22). DOI: 10.1063/1.4936757.

65.Llobet, J.; Sansa, M.; Lorenzoni, M.; Borrise, X.; Paulo, A. S.; Perez-Murano, F., Tuning piezoresistive transduction in nanomechanical resonators by geometrical asymmetries. Applied Physics Letters 2015, 107 (7). DOI: 10.1063/1.4928709.

66.Lopez-Polin, G.; Gomez-Navarro, C.; Parente, V.; Guinea, F.; Katsnelson, M. I.; Perez-Murano, F.; Gomez-Herrero, J., Increasing the elastic modulus of graphene by controlled defect creation. Nature Physics 2015, 11 (1), 26-31. DOI: 10.1038/nphys3183.

67.Lorenzoni, M.; Evangelio, L.; Nicolet, C.; Navarro, C.; Paulo, A. S.; Perez-Murano, F., Nanomechanical properties of solvent cast PS and PMMA polymer blends and block co-polymers. In Alternative Lithographic Technologies Vii, Resnick, D. J.; Bencher, C., Eds. 2015; Vol. 9423. DOI: 94232510.1117/12.2085829.

68.Lorenzoni, M.; Evangelio, L.; Nicolet, C.; Navarro, C.; San Paulo, A.; Rius, G.; Perez-Murano, F., Nanomechanical properties of solvent cast polystyrene and poly(methyl methacrylate) polymer blends and self-assembled block copolymers. Journal of Micro-Nanolithography Mems and Moems 2015, 14 (3). DOI: 10.1117/1.jmm.14.3.033509.

69.Lorenzoni, M.; Evangelio, L.; Verhaeghe, S.; Nicolet, C.; Navarro, C.; Perez-Murano, F., Assessing the Local Nanomechanical Properties of Self-Assembled Block Copolymer Thin Films by Peak Force Tapping. Langmuir 2015, 31 (42), 11630-11638. DOI: 10.1021/acs.langmuir.5b02595.

70.Lorenzoni, M.; Giugni, A.; Di Fabrizio, E.; Perez-Murano, F.; Mescola, A.; Torre, B., Nanoscale reduction of graphene oxide thin films and its characterization. Nanotechnology 2015, 26 (28). DOI: 10.1088/0957-4484/26/28/285301.

71.Lupu, S.; Lete, C.; del Campo, F. J., Dopamine Electroanalysis Using Electrochemical Biosensors Prepared by a Sinusoidal Voltages Method. Electroanalysis 2015, 27 (7), 1649-1659. DOI: 10.1002/elan.201400680.

72.Macias-Montero, J. G.; Sarraj, M.; Chmeissani, M.; Martinez, R.; Puigdengoles, C., A 2D 4x4 Channel Readout ASIC for Pixelated CdTe Detectors for Medical Imaging Applications. Ieee Transactions on Nuclear Science 2015, 62 (5), 2327-2333. DOI: 10.1109/tns.2015.2465377.

73.Maeso-Diaz, R.; Illa, X.; Vila, S.; Yeste, J.; Marrone, G.; Navarro-Zornoza, M.; Peralta, C.; Villa, R.; Gracia-Sancho, J., THE LIVER SINUSOID WITHIN A MICROFLUIDIC CHAMBER: A NEW TOOL FOR VASCULAR BIOLOGY RESEARCH. Journal of Hepatology 2015, 62, S339-S340.

74.Maestro, M.; Martin-Martinez, J.; Diaz, J.; Crespo-Yepes, A.; Gonzalez, M. B.; Rodriguez, R.; Campabadal, F.; Nafria, M.; Aymerich, X., Analysis of Set and Reset mechanisms in Ni/HfO2-based RRAM with fast ramped voltages. Microelectronic Engineering 2015, 147, 176-179. DOI: 10.1016/j.mee.2015.04.057.

75.Margarit, J. M.; Vergara, G.; Villamayor, V.; Gutierrez-Alvarez, R.; Fernandez-Montojo, C.; Teres, L.; Serra-Graells, F., A 2 kfps Sub-mu W/Pix Uncooled-PbSe Digital Imager With 10 Bit DR Adjustment and FPN Correction for High-Speed and Low-Cost MWIR Applications. Ieee Journal of Solid-State Circuits 2015, 50 (10), 2394-2405. DOI: 10.1109/jssc.2015.2464672.

76.Marigo, E.; Sansa, M.; Perez-Murano, F.; Uranga, A.; Barniol, N., Top-Down CMOS-NEMS Polysilicon Nanowire with Piezoresistive Transduction. Sensors 2015, 15 (7), 17036-17047. DOI: 10.3390/s150717036.

77.Marquez, S.; Alvarez, M.; Farina, D.; Dominguez, C.; Lechuga, L. M., Simulation and characterization of hollow microbridge resonators for label-free biosensing. In Bio-Mems and Medical Microdevices Ii, VanDenDriesche, S., Ed. 2015; Vol. 9518. DOI: 95180u10.1117/12.2178981.

78.Martinez-Tong, D. E.; Rodriguez-Rodriguez, A.; Nogales, A.; Garcia-Gutierrez, M. C.; Perez-Murano, F.; Llobet, J.; Ezquerra, T. A.; Rebollar, E., Laser Fabrication of Polymer Ferroelectric Nanostructures for Nonvolatile Organic Memory Devices. Acs Applied Materials & Interfaces 2015, 7 (35), 19611-19618. DOI: 10.1021/acsami.5b05213.

79.Matatagui, D.; Fernandez, M. J.; Fontecha, J. L.; Santos, J. P.; Gracia, I.; Cane, C.; Horrillo, M. C., Propagation of acoustic waves in metal oxide nanoparticle layers with catalytic metals for selective gas detection. Sensors and Actuators B-Chemical 2015, 217, 65-71. DOI: 10.1016/j.snb.2014.12.076.

80.Mitra, K. Y.; Sowade, E.; Martinez-Domingo, C.; Ramon, E.; Carrabina, J.; GornesD, F. L.; Baumann, R. R., Potential Up-scaling of Inkjet-Printed Devices for Logical Circuits in Flexible Electronics. In International Conferences and Exhibition on Nanotechnologies & Organic Electronics, Logothetidis, S.; Laskarakis, A.; Gravalidis, C., Eds. 2015; Vol. 1646, pp 106-114. DOI: 10.1063/1.4908590.

81.Moral-Vico, J.; Barallat, J.; Abad, L.; Olive-Monllau, R.; Munoz-Pascual, F. X.; Ortega, A. G.; del Campo, F. J.; Baldrich, E., Dual chronoamperometric detection of enzymatic biomarkers using magnetic beads and a low-cost flow cell. Biosensors & Bioelectronics 2015, 69, 328-336. DOI: 10.1016/j.bios.2015.02.042.

82.Moya, A.; Guimera, X.; del Campo, F. J.; Prats-Alfonso, E.; Dorado, A.; Baeza, M.; Villa, R.; Gabriel, D.; Gamisans, X.; Gabriel, G., Profiling of oxygen in biofilms using individually addressable disk microelectrodes on a microfabricated needle. Microchimica Acta 2015, 182 (5-6), 985-993. DOI: 10.1007/s00604-014-1405-4.

83.Murillo, G.; Agust, J.; Abadal, G., Self-suspended vibration-driven energy harvesting chip for power density maximization. Smart Materials and Structures 2015, 24 (11). DOI: 10.1088/0964-1726/24/11/115027.

84.Navarro-Zornoza, M.; Illa, X.; Peralta, C.; Villa, R.; Gracia-Sancho, J., Enhancing hepatocyte function using an advanced microfluidic system for clinical and pharmaceutical applications. Hepatology 2015, 62, 211A-212A.

85.Niu, P. F.; Fernandez-Sanchez, C.; Gich, M.; Ayora, C.; Roig, A., Electroanalytical Assessment of Heavy Metals in Waters with Bismuth Nanoparticle-Porous Carbon Paste Electrodes. Electrochimica Acta 2015, 165, 155-161. DOI: 10.1016/j.electacta.2015.03.001.

86.Novo, S.; Mora-Espi, I.; Gomez-Martinez, R.; Barrios, L.; Ibanez, E.; Such, X.; Duch, M.; Mora, X.; Plaza, J. A.; Nogues, C., Traceability of human sperm samples by direct tagging with polysilicon microbarcodes. Reproductive Biomedicine Online 2015, 31 (2), 162-170. DOI: 10.1016/j.rbmo.2015.04.012.

87.Otte, M. A.; Solis-Tinoco, V.; Prieto, P.; Borrise, X.; Lechuga, L. M.; Gonzalez, M. U.; Sepulveda, B., Tailored Height Gradients in Vertical Nanowire Arrays via Mechanical and Electronic Modulation of Metal-Assisted Chemical Etching. Small 2015, 11 (33), 4201-4208. DOI: 10.1002/smll.201500175.

88.Perpina, X.; Werkhoven, R. J.; Vellvehi, M.; Jakovenko, J.; Jorda, X.; Kunen, J. M. G.; Bancken, P.; Bolt, P. J., Thermal Analysis of LED Lamps for Optimal Driver Integration. Ieee Transactions on Power Electronics 2015, 30 (7), 3876-3891. DOI: 10.1109/tpel.2014.2346543.

89.Phulpin, T.; Tremouilles, D.; Isoird, K.; Tournier, D.; Godignon, P.; Austin, P., Failure analysis of ESD-stressed SiC MESFET. Microelectronics Reliability 2015, 55 (9-10), 1542-1548. DOI: 10.1016/j.microrel.2015.06.121.

90.Phulpin, T.; Tremouilles, D.; Isoird, K.; Tournier, D.; Godignon, P.; Austin, P.; Ieee, An Electrostatic-Discharge-Protection Solution for Silicon-Carbide MESFET. In 2015 37th Electrical Overstress/Electrostatic Discharge Symposium, 2015.

91.Pla, D.; Salleras, M.; Garbayo, I.; Morata, A.; Sabate, N.; Divins, N. J.; Llorca, J.; Tarancon, A., Fabrication and characterization of a fuel flexible micro-reformer fully integrated in silicon for micro-solid oxide fuel cell applications. In Smart Sensors, Actuators, and Mems Vii; and Cyber Physical Systems, SanchezRojas, J. L.; Brama, R., Eds. 2015; Vol. 9517. DOI: 95172d10.1117/12.2178860.

92.Pla, D.; Salleras, M.; Garbayo, I.; Morata, A.; Sabate, N.; Divins, N. J.; Llorca, J.; Tarancon, A., FABRICATION AND CHARACTERIZATION OF A MICRO-REFORMER UNIT FULLY INTEGRATED IN SILICON FOR ETHANOL CONVERSION. 2015; p 105-110.

93.Pla, D.; Sanchez-Gonzalez, A.; Garbayo, I.; Salleras, M.; Morata, A.; Tarancon, A., Is it possible to design a portable power generator based on micro-solid oxide fuel cells? A finite volume analysis. Journal of Power Sources 2015, 293, 264-273. DOI: 10.1016/j.jpowsour.2015.05.046.

94.Pristavu, G.; Brezeanu, G.; Badila, M.; Pascu, R.; Danila, M.; Godignon, P., A model to non-uniform Ni Schottky contact on SiC annealed at elevated temperatures. Applied Physics Letters 2015, 106 (26). DOI: 10.1063/1.4923468.

95.Pujol-Vila, F.; Vigues, N.; Diaz-Gonzalez, M.; Munoz-Berbel, X.; Mas, J., Fast and sensitive optical toxicity bioassay based on dual wavelength analysis of bacterial ferricyanide reduction kinetics. Biosensors & Bioelectronics 2015, 67, 272-279. DOI: 10.1016/j.bios.2014.08.030.

96.Rio-Cristobal, A.; Guimera, A.; Traver, E.; Morejon, A.; Herrero, C.; Villa, R.; Jonuscheit, S.; Martin, R.; Maldonado, M. J., Study of the corneal epithelial and endothelial permeability in a contact lens human model using a new non-invasive bioimpedance method. Investigative Ophthalmology & Visual Science 2015, 56 (7).

97.Rius, C.; Ackermann, T. N.; Dorado, B.; Munoz-Berbel, X.; Andres, V.; Llobera, A., Fiber Optic Label-Free Biophotonic Diagnostic Tool for Cardiovascular Disease. In Bio-Mems and Medical Microdevices Ii, VanDenDriesche, S., Ed. 2015; Vol. 9518. DOI: 95180v 10.1117/12.2179062.

98.Rius, G.; Lorenzoni, M.; Matsui, S.; Tanemura, M.; Perez-Murano, F., Boosting the local anodic oxidation of silicon through carbon nanofiber atomic force microscopy probes. Beilstein Journal of Nanotechnology 2015, 6, 215-222. DOI: 10.3762/bjnano.6.20.

99.Rodriguez, A. F.; Basaran, A. C.; Morales, R.; Kovylina, M.; Llobet, J.; Borrise, X.; Marcus, M. A.; Scholl, A.; Schuller, I. K.; Batlle, X.; Labarta, A., Manipulation of competing ferromagnetic and antiferromagnetic domains in exchange-biased nanostructures. Physical Review B 2015, 92 (17). DOI: 10.1103/PhysRevB.92.174417.

100.Rodriguez, A.; Gonzalez, M. B.; Campabadal, F.; Sune, J.; Miranda, E., Breakdown time statistics of successive failure events in constant voltage-stressed Al2O3/HfO2 nanolaminates. Microelectronic Engineering 2015, 147, 85-88. DOI: 10.1016/j.mee.2015.04.048.

101.Rodriguez, A.; Gonzalez, M. B.; Campabadal, F.; Sune, J.; Miranda, E., Electrical characterization of multiple leakage current paths in HfO2/Al2O3-based nanolaminates. Microelectronics Reliability 2015, 55 (9-10), 1442-1445. DOI: 10.1016/j.microrel.2015.05.018.

102.Rodriguez, A.; Gonzalez, M. B.; Miranda, E.; Campabadal, F.; Sune, J., Temperature and polarity dependence of the switching behavior of Ni/HfO2-based RRAM devices. Microelectronic Engineering 2015, 147, 75-78. DOI: 10.1016/j.mee.2015.04.038.

103.Rodriguez-Ruiz, I.; Conejero-Muriel, M.; Ackermann, T. N.; Gavira, J. A.; Llobera, A., A multiple path photonic lab on a chip for parallel protein concentration measurements. Lab on a Chip 2015, 15 (4), 1133-1139. DOI: 10.1039/c4lc01332h.

104.Rodriguez-Ruiz, I.; Masvidal-Codina, E.; Ackermann, T. N.; Llobera, A., Photonic lab-on-chip (PhLOC) for enzyme-catalyzed reactions in continuous flow. Microfluidics and Nanofluidics 2015, 18 (5-6), 1277-1286. DOI: 10.1007/s10404-014-1526-4.

105.Rosado, J.; Hidalgo, S., Characterization and modeling of crosstalk and afterpulsing in Hamamatsu silicon photomultipliers. Journal of Instrumentation 2015, 10. DOI: 10.1088/1748-0221/10/10/p10031.

106.Sanahuja, D.; Gimenez-Gomez, P.; Vigues, N.; Ackermann, T. N.; Guerrero-Navarro, A. E.; Pujol-Vila, F.; Sacristan, J.; Santamaria, N.; Sanchez-Contreras, M.; Diaz-Gonzalez, M.; Mas, J.; Munoz-Berbel, X., Microbial trench-based optofluidic system for reagentless determination of phenolic compounds. Lab on a Chip 2015, 15 (7), 1717-1726. DOI: 10.1039/c4lc01446d.

107.Soccio, M.; Rueda, D. R.; Garcia-Gutierrez, M. C.; Alayo, N.; Perez-Murano, F.; Lotti, N.; Munari, A.; Ezquerra, T. A., Morphology of poly(propylene azelate) gratings prepared by nanoimprint lithography as revealed by atomic force microscopy and grazing incidence X-ray scattering. Polymer 2015, 61, 61-67. DOI: 10.1016/j.polymer.2015.01.066.

108.Soler, V.; Berthou, M.; Mihaila, A.; Montserrat, J.; Godignon, P.; Rebollo, J.; Millan, J., Experimental analysis of planar edge terminations for high voltage 4H-SiC devices. In Essderc 2015 Proceedings of the 45th European Solid-State Device Research Conference, Pribyl, W.; Grasser, T.; Schrems, M., Eds. 2015; pp 68-71.

109.Sutula, S.; Dei, M.; Teres, L.; Serra-Graells, F.; Ieee, Class-AB Single-Stage OpAmp for Low-Power Switched-Capacitor Circuits. In 2015 Ieee International Symposium on Circuits and Systems, 2015; pp 2081-2084.

110.Vallejos, S.; Gracia, I.; Bravo, J.; Figueras, E.; Hubalek, J.; Cane, C., Detection of volatile organic compounds using flexible gas sensing devices based on tungsten oxide nanostructures functionalized with Au and Pt nanoparticles. Talanta 2015, 139, 27-34. DOI: 10.1016/j.talanta.2015.02.034.

111.Vallejos, S.; Gracia, I.; Figueras, E.; Cane, C., Nanoscale Heterostructures Based on Fe2O3@WO3-x Nanoneedles and Their Direct Integration into Flexible Transducing Platforms for Toluene Sensing. Acs Applied Materials & Interfaces 2015, 7 (33), 18638-18649. DOI: 10.1021/acsami.5b05081.

112.Vargas-Estevez, C.; Robaina, R. R.; del Real, R. P.; Plaza, J. A., Nanometric Metal-Film Thickness Measurement Based on a Planar Spiral Coils Stack. Ieee Transactions on Nanotechnology 2015, 14 (2), 297-303. DOI: 10.1109/tnano.2015.2392794.

113.Vidal-Alvarez, G.; Agusti, J.; Torres, F.; Abadal, G.; Barniol, N.; Llobet, J.; Sansa, M.; Fernandez-Regulez, M.; Perez-Murano, F.; Paulo, A. S.; Gottlieb, O., Top-down silicon microcantilever with coupled bottom-up silicon nanowire for enhanced mass resolution. Nanotechnology 2015, 26 (14). DOI: 10.1088/0957-4484/26/14/145502.

114.Vidal-Alvarez, G.; Agusti, J.; Torres, F.; Abadal, G.; Barniol, N.; Llobet, J.; Sansa, M.; Fernandez-Regulez, M.; Perez-Murano, F.; San Paulo, A.; Gottlieb, O., Top-down silicon microcantilever with coupled bottom-up silicon nanowire for enhanced mass resolution (vol 26, 145502, 2015). Nanotechnology 2015, 26 (25). DOI: 10.1088/0957-4484/26/25/259601.

115.Vila, F.; Pallares, J.; Conde, A.; Teres, L.; Ieee, A Fully-Automated Methodology and System for Printed Electronics Foil Characterization. In Proceedings of the 2015 Ieee International Conference on Microelectronic Test Structures, 2015; pp 188-192.

116.Villena, M. A.; Gonzalez, M. B.; Roldan, J. B.; Campabadal, F.; Jimenez-Molinos, F.; Gomez-Campos, F. M.; Sune, J., An in-depth study of thermal effects in reset transitions in HfO2 based RRAMs. Solid-State Electronics 2015, 111, 47-51. DOI: 10.1016/j.sse.2015.04.008.

117.Voitechovic, E.; Bratov, A.; Abramova, N.; Razumiene, J.; Kirsanov, D.; Legin, A.; Lakshmi, D.; Piletsky, S.; Whitcombe, M.; Ivanova-Mitseva, P. K., Development of label-free impedimetric platform based on new conductive polyaniline polymer and three-dimensional interdigitated electrode array for biosensor applications. Electrochimica Acta 2015, 173, 59-66. DOI: 10.1016/j.electacta.2015.05.011.

118.Yeste, J.; Illa, X.; Guimera, A.; Villa, R., A novel strategy to monitor microfluidic in-vitro blood brain barrier models using impedance spectroscopy. In Bio-Mems and Medical Microdevices Ii, VanDenDriesche, S., Ed. 2015; Vol. 9518. DOI: 95180n10.1117/12.2180567.

119.Zadorozhnaya, O.; Kirsanov, D.; Buzhinsky, I.; Tsarev, F.; Abramova, N.; Bratov, A.; Munoz, F. J.; Ribo, J.; Bori, J.; Riva, M. C.; Legin, A., Water pollution monitoring by an artificial sensory system performing in terms of Vibrio fischeri bacteria. Sensors and Actuators B-Chemical 2015, 207, 1069-1075. DOI: 10.1016/j.snb.2014.08.056.

Papers Not Web of Science

1.Abramova, N.; Bratov, A., Application of Photocured Polymer Ion Selective Membranes for Solid-State Chemical Sensors.Chemosensors 2015, vol. 3, 190-199.

2.Brull, M.; Gutiérrez, M.; Jimenez-Jorquera, C., El análisis organoléptico del agua de consumo humano utilizando microsensores.Tecnoaqua 2015,15, 76-82.

3.Florentin, M.; Rafí, J.M.; Chevallier, F.G.; Soler Rosales, V.; Konczewicz, L.; Contreras, S.; Juillaguet, S.; Montserrat, J.; Godignon, P., Study of Geometrical Effects in Charge Pumping Current for Lateral SiC nMOSFETs Electrical Characterization.Materials Science Forum 2015, vol. 821-823, 717-720.

Full Review William Hill www.wbetting.co.uk